Product Details:
Payment & Shipping Terms:
|
Type: | Medical Device | OEM: | OK |
---|---|---|---|
Market: | Global World | Operating Temperture: | Temperature: 0℃ To 40 ℃ |
Operating Humidity: | Humidity: ≤80% | Operating Atmospheric Pressure: | Atmospheric Pressure: 70kPa To106kPa |
Power Requirements: | AC Input: 100 To 240 VAC (50Hz / 60Hz), DC Output: 12 VDC | Method: | Volume-clamp Methodology |
Highlight: | hospital surgical equipment,medical surgical instruments |
Noninvasive Continuous Instantaneous Blood Pressure Monitor
Introduction
BP100A uses a wrist unit to measure non-invasively, real time and continuous arterial blood pressure. It based on the volume-clamp methodology.It provides reliable, continuous, precision and noninvasive measurements for any occasion where invasive arterial lines are not indicated and NBP is not sufficient, which can satisfy the requirements of the operating rooms and intensive care units for continuous BP measurement with accuracy, precision, reliability and convenience, as well as the performance on lessening the impact of motion artifacts and absence of the effects on the blood circulation of the limb to be measured, which is beneficial for the physicians diagnostic with the patients treatment.
Indication for Use
For apply to the patients who must get a fast and accurate for long duration of monitoring continuous BP waveforms and beat-to-beat pressure values at any occasions, for instance, in anesthesia, operation as well as intensive care, etc.
Contra-indication
1. Serious cardiac arrhythmia patients
2. The special patient whose radial artery is malformation or wrist anatomy is abnormal.
3. Allen testing positive patients
4. The patient of upper limbs with trauma, skin lesion, or infection & necrosis.
Key Features
1. Non-Invasive & Safe
Painless, stress-free and without any risk to the patient
2. Instantaneous & Continuous
Beat–to–beat continuous non-invasive BP measurement and real –time the radial BP waveform.
3. Calibration-Free
Without any calibration, fast and accurate measurement
4. Movement resistant
It has strong anti-dynamic performance for patients.
5. Long Time Monitoring
As for monitoring the blood pressure of the radial artery on wrist, it is minimal effect on blood circulation with nerve conduction. It can be used for monitoring in a long time.
6. High Accuracy
It can be continuously to monitor the blood pressure of patients in low perfusion, shock with weak pulse.
Key Indicators
1. Measuring Range:
SBP: 40-250mmHg DBP: 15-215mmHg
MBP: 30-250mmHg PR: 30-250bpm
2. Resolution of Measurement:
Blood Pressure: 1mmHg Pulse Rate: 1 beat/min
3. Alarms: Physiological -medium priority Technical - low priority
Physical Parameter
1. Size: 318mm x 152mm x 264mm
2. Weight: 5.5kg
Operating Environmental
1. Temperature: 0℃ to 40 ℃
2. Humidity: ≤80%
3. Atmospheric pressure: 70kPa to106kPa
Power Requirements
1. AC input: 100 to 240 VAC (50Hz / 60Hz)
2. DC output: 12 VDC
The operation way is in the following:
1. Fix the wrist restraint
2. Make mark
3. Place the wrist positioning pad
4. Apply the wrist sensor
5. Start the measurement
Application:
For apply to the patients who must get the real time blood pressure value with waveform in a long time continuous with safe monitoring at all occasions.